The Dryer and Reactivator with NIR lamps has been developed with cutting-edge technology for the drying and reactivation of adhesives in the footwear industry. This equipment features a hybrid system, designed to efficiently meet the diverse demands of materials and adhesives used in the sector, ensuring consistent and high-quality results.

 

Equipment features:

  • 100% reactivation system with NIR lamps, providing high efficiency.
  • Hybrid drying system, combining different technologies for optimized results.
  • Independent drying tunnel for sole and upper, ensuring precise control for each part of the footwear.
  • Independent drying temperature control for sole and upper, ensuring a uniform and high-quality process.
  • Independent ventilation for sole and upper, ensuring adequate and uniform airflow.
  • Directed heating and circulation, ensuring consistency and efficiency throughout the process.
  • Lower conveyor belt closure system, ensuring greater safety and efficiency in transportation.
  • Independent reactivation for sole and upper, allowing personalized adjustments for different types of footwear.
  • Easy access for maintenance, optimizing service time and practicality.
  • Advanced control via PLC, with customizable programming parameters for total process control.

 

• Independent temperature adjustment for:

Left tunnel temperature (programmed and actual)

Right tunnel temperature (programmed and actual)

Sole reactivation temperature (programmed and actual)

Upper reactivation temperature (programmed and actual)

Elapsed time

Conveyor time

 

• Adjustment for sole reactivation:

Heating power in %

Desired temperature

Temperature offset

Heating cycle

 

• Adjustment for lateral upper reactivation:

Heating power in %

Desired temperature

Temperature offset

Heating cycle

 

• Adjustment for toe upper reactivation:

Heating power in %

Desired temperature

Temperature offset

Heating cycle

 

• Adjustment for rear upper reactivation:

Heating power in %

Desired temperature

Temperature offset

Heating cycle

 

 

• Adjustment for tunnel resistance:

Desired left temperature

Desired right temperature

 

 

• Adjustment for heating tunnel lamps L1/L2/L3/L4/L5:

Sole power in %

Upper power in %

Sole heating cycle in sec.

Upper heating cycle in sec.

 

 

• Conveyor movement times:

Reactivation time

Mold return time

Fine adjustment of upper and sole position in reactivation

Fine adjustment of upper and sole return in reactivation

Maximum reactivation time

 

• Hour meter
• Piece counter

 

Differentiators:

  • Precise monitoring and control of temperature, with a sensor that measures the actual reactivation temperature for greater accuracy in the process.
  • Smart entry sensor that activates the lamps only when footwear is present, ensuring energy efficiency.
  • Drying and reactivation system that only releases the footwear when the programmed temperature is reached, ensuring process quality.
  • Centralized air circulation system, providing higher efficiency and reducing energy consumption.
  • Independent control of air flow and exchange for the sole and upper, optimized for each part of the footwear.
  • Reactivation temperature reuse system for the drying process, promoting energy savings.
  • Fault monitoring system, ensuring continuous operation and minimizing interruptions.
  • Adjustment of the reactivation chamber height, offering flexibility for different shoe sizes.
  • Automatic positioning system for the upper and self-molding conveyor belts, adapting to any footwear model.

 

Options:

  • Machine Voltage: 220 V or 380 V – Three Phase
  • Machine Frequency: 50 Hz or 60 Hz
Request proposal
Technical table
Length 3.590 mm
Width 995 mm
Height 1.715 mm
Weight 835 kg
Installed Power 20.685 Watts
Reactivation temperature 0°c à 200 °c
Drying temperature 0°c à 90 °c
Ventilation power 1500 Watts
Number of operating positions Calçados em espera – 7 pés / Calçados em secagem – 10 pés / Calçados em reativação – 1 pé
Useful area of the leather reactivation tunnel 400 mm – Largura / 215 mm - Comprimento / 40 à 70 mm – Altura
Useful area of the sole reactivation tunnel 400 mm – Largura / 215 mm - Comprimento / 70 à 100 mm – Altura